Coquitlam Mall Seismic Upgrading
We completed seismic brick upgrades at the mall, enhancing both safety and structural integrity while maintaining the building’s aesthetic appeal.

Coquitlam Mall experienced a wall failure when shelf angles dropped, causing sections of the wall to collapse. Engineers determined that the building required seismic upgrades. Our work involved opening sections of the wall. In some areas, we replaced the entire wall, while in others, we replaced only the shelf angle.
We drilled into the steel to install anchor bolts, then applied Blueskin membrane and mastic, ensuring all joints were properly overlapped. In areas rebuilt with new brick, we installed wall ties, and Helifix ties were also added to the existing brickwork for additional support.
The mall remained open throughout the project, so safety was our top priority. An abatement crew was on-site to remove asbestos, and we stayed vigilant around all identified areas of concern.
The main challenge was constructing the room with three exterior walls and a one-inch cavity between them. Steel stud framing was in place before we started, limiting our space to build. Before the framing went up, we laid out and installed seismic supports at the ceiling so they could be fire-sealed and made airtight around the Hardy board. Precise layout and placement of the seismic restraints were essential to maintain the cavity dimension. Our main concern was preventing mortar or concrete from entering the cavity, as even a single blockage would prevent the equipment from getting accurate readings. Because the adjacent equipment was sensitive, the wall assembly also had to meet strict acoustic requirements. Rebar was installed to specification and thoroughly cleaned before the pour, and all joints had to be sealed to prevent concrete from leaking into the cavity.